§ 23.7. Intensity Specifications.  


Latest version.
  • Illuminance levels for outdoor lighting fixtures shall comply with the standards in Table 23.1, measured at three feet above the ground or finished grade.

    Table 23.1

    Outdoor Lighting Intensity Regulations

    At Property Lines Including Rights-of-Way Minimum
    Footcandles
    Maximum
    Footcandles
    At property line abutting a residential use None 0.5
    At property line abutting an office or institutional use None 1.0
    At property line abutting a commercial or industrial use None 1.5

     

    Off-Street Parking Lots Minimum
    Footcandles
    Average
    Footcandles
    Maximum
    Footcandles
    Residential areas 0.5 2 4
    Office-professional areas 1.0 3 6
    Commercial areas 2.0 6 12
    Industrial areas 1.0 4 8"

     

    _____

( Ord. No. 348-13, § 10, 8-18-2011 )